Fairfax County, VA, excluding the incorporated towns, which run their own zoning.
| District | Properties loaded | Code | What says so |
|---|---|---|---|
| C-1 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 94 no ZIP in the county's record (5), 22003 (50), 22015 (37), 22044 (2) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "C-1", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| C-1 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 94 no ZIP in the county's record (5), 22003 (50), 22015 (37), 22044 (2) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "C-1", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| C-2 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 1,255 no ZIP in the county's record (20), 20120 (3), 20121 (4), 22003 (189), 22015 (120), 22027 (10), 22030 (1), 22031 (12), 22032 (38), 22041 (88), 22042 (2), 22043 (15), 22044 (85), 22066 (1), 22101 (54), 22124 (38), 22150 (5), 22151 (57), 22152 (63), 22153 (3), 22181 (12), 22182 (62), 22302 (19), 22303 (1), 22306 (35), 22307 (57), 22308 (2), 22309 (3), 22310 (188), 22312 (68) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "C-2", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| C-2 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 1,255 no ZIP in the county's record (20), 20120 (3), 20121 (4), 22003 (189), 22015 (120), 22027 (10), 22030 (1), 22031 (12), 22032 (38), 22041 (88), 22042 (2), 22043 (15), 22044 (85), 22066 (1), 22101 (54), 22124 (38), 22150 (5), 22151 (57), 22152 (63), 22153 (3), 22181 (12), 22182 (62), 22302 (19), 22303 (1), 22306 (35), 22307 (57), 22308 (2), 22309 (3), 22310 (188), 22312 (68) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "C-2", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| C-3 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 730 no ZIP in the county's record (45), 20121 (3), 20170 (1), 20171 (3), 20191 (3), 22003 (286), 22030 (2), 22031 (71), 22033 (2), 22041 (4), 22042 (45), 22043 (98), 22044 (6), 22046 (1), 22079 (1), 22101 (10), 22102 (16), 22150 (8), 22182 (77), 22302 (1), 22303 (2), 22306 (1), 22307 (4), 22309 (1), 22310 (30), 22312 (9) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "C-3", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| C-3 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 730 no ZIP in the county's record (45), 20121 (3), 20170 (1), 20171 (3), 20191 (3), 22003 (286), 22030 (2), 22031 (71), 22033 (2), 22041 (4), 22042 (45), 22043 (98), 22044 (6), 22046 (1), 22079 (1), 22101 (10), 22102 (16), 22150 (8), 22182 (77), 22302 (1), 22303 (2), 22306 (1), 22307 (4), 22309 (1), 22310 (30), 22312 (9) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "C-3", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| C-4 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 73 no ZIP in the county's record (13), 22003 (1), 22030 (19), 22041 (2), 22042 (3), 22043 (1), 22102 (21), 22150 (5), 22182 (8) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "C-4", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| C-4 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 73 no ZIP in the county's record (13), 22003 (1), 22030 (19), 22041 (2), 22042 (3), 22043 (1), 22102 (21), 22150 (5), 22182 (8) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "C-4", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| C-5 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 476 no ZIP in the county's record (43), 20170 (1), 20171 (2), 20191 (1), 22003 (18), 22015 (2), 22027 (2), 22030 (1), 22031 (24), 22033 (1), 22039 (5), 22041 (19), 22042 (26), 22043 (6), 22044 (2), 22046 (1), 22066 (1), 22079 (9), 22101 (29), 22102 (7), 22124 (15), 22150 (11), 22151 (1), 22180 (3), 22182 (24), 22303 (108), 22306 (27), 22307 (3), 22308 (7), 22309 (41), 22310 (17), 22312 (14), 22315 (5) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "C-5", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| C-5 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 476 no ZIP in the county's record (43), 20170 (1), 20171 (2), 20191 (1), 22003 (18), 22015 (2), 22027 (2), 22030 (1), 22031 (24), 22033 (1), 22039 (5), 22041 (19), 22042 (26), 22043 (6), 22044 (2), 22046 (1), 22066 (1), 22079 (9), 22101 (29), 22102 (7), 22124 (15), 22150 (11), 22151 (1), 22180 (3), 22182 (24), 22303 (108), 22306 (27), 22307 (3), 22308 (7), 22309 (41), 22310 (17), 22312 (14), 22315 (5) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "C-5", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| C-6 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 697 no ZIP in the county's record (73), 20120 (2), 20121 (39), 20124 (6), 20151 (21), 20170 (5), 20171 (11), 22003 (88), 22015 (7), 22027 (5), 22030 (8), 22031 (45), 22032 (2), 22033 (4), 22039 (1), 22041 (83), 22042 (13), 22043 (1), 22044 (1), 22066 (24), 22079 (12), 22101 (69), 22102 (3), 22106 (1), 22150 (87), 22151 (4), 22152 (10), 22153 (5), 22180 (1), 22182 (8), 22303 (6), 22306 (16), 22307 (4), 22308 (1), 22309 (4), 22310 (9), 22312 (17), 22315 (1) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "C-6", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| C-6 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 697 no ZIP in the county's record (73), 20120 (2), 20121 (39), 20124 (6), 20151 (21), 20170 (5), 20171 (11), 22003 (88), 22015 (7), 22027 (5), 22030 (8), 22031 (45), 22032 (2), 22033 (4), 22039 (1), 22041 (83), 22042 (13), 22043 (1), 22044 (1), 22066 (24), 22079 (12), 22101 (69), 22102 (3), 22106 (1), 22150 (87), 22151 (4), 22152 (10), 22153 (5), 22180 (1), 22182 (8), 22303 (6), 22306 (16), 22307 (4), 22308 (1), 22309 (4), 22310 (9), 22312 (17), 22315 (1) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "C-6", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| C-7 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 105 no ZIP in the county's record (24), 20120 (2), 20121 (3), 22003 (1), 22033 (10), 22044 (12), 22102 (9), 22150 (13), 22182 (31) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "C-7", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| C-7 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 105 no ZIP in the county's record (24), 20120 (2), 20121 (3), 22003 (1), 22033 (10), 22044 (12), 22102 (9), 22150 (13), 22182 (31) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "C-7", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| C-8 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 1,213 no ZIP in the county's record (118), 20120 (32), 20121 (10), 20124 (1), 20151 (46), 20164 (1), 20170 (9), 20171 (4), 20190 (1), 22003 (41), 22030 (16), 22031 (16), 22033 (2), 22039 (1), 22041 (73), 22042 (135), 22043 (12), 22044 (13), 22046 (29), 22060 (3), 22066 (102), 22079 (21), 22101 (40), 22102 (7), 22124 (2), 22150 (21), 22151 (2), 22181 (3), 22182 (14), 22302 (2), 22303 (46), 22306 (121), 22307 (2), 22309 (223), 22310 (8), 22312 (36) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "C-8", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| C-8 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 1,213 no ZIP in the county's record (118), 20120 (32), 20121 (10), 20124 (1), 20151 (46), 20164 (1), 20170 (9), 20171 (4), 20190 (1), 22003 (41), 22030 (16), 22031 (16), 22033 (2), 22039 (1), 22041 (73), 22042 (135), 22043 (12), 22044 (13), 22046 (29), 22060 (3), 22066 (102), 22079 (21), 22101 (40), 22102 (7), 22124 (2), 22150 (21), 22151 (2), 22181 (3), 22182 (14), 22302 (2), 22303 (46), 22306 (121), 22307 (2), 22309 (223), 22310 (8), 22312 (36) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "C-8", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| I-2 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 5 no ZIP in the county's record (2), 20171 (1), 20191 (2) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "I-2", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| I-2 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 5 no ZIP in the county's record (2), 20171 (1), 20191 (2) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "I-2", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| I-3 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 274 no ZIP in the county's record (26), 20151 (131), 20190 (5), 20191 (75), 22015 (2), 22041 (2), 22042 (2), 22102 (22), 22150 (7), 22182 (2) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "I-3", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| I-3 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 274 no ZIP in the county's record (26), 20151 (131), 20190 (5), 20191 (75), 22015 (2), 22041 (2), 22042 (2), 22102 (22), 22150 (7), 22182 (2) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "I-3", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| I-4 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 475 no ZIP in the county's record (38), 20151 (108), 20170 (2), 20171 (16), 20190 (14), 20191 (55), 20196 (1), 22030 (3), 22031 (40), 22042 (3), 22043 (1), 22079 (65), 22102 (3), 22150 (5), 22151 (11), 22152 (6), 22160 (1), 22182 (83), 22310 (13), 22312 (3), 22315 (4) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "I-4", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| I-4 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 475 no ZIP in the county's record (38), 20151 (108), 20170 (2), 20171 (16), 20190 (14), 20191 (55), 20196 (1), 22030 (3), 22031 (40), 22042 (3), 22043 (1), 22079 (65), 22102 (3), 22150 (5), 22151 (11), 22152 (6), 22160 (1), 22182 (83), 22310 (13), 22312 (3), 22315 (4) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "I-4", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| I-5 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 1,876 no ZIP in the county's record (147), 20121 (142), 20151 (423), 20153 (1), 20171 (58), 20190 (67), 20191 (3), 22015 (28), 22030 (54), 22031 (134), 22032 (4), 22039 (4), 22042 (29), 22043 (23), 22046 (4), 22079 (214), 22082 (1), 22102 (35), 22150 (61), 22151 (63), 22153 (177), 22161 (1), 22180 (2), 22182 (47), 22303 (2), 22310 (36), 22312 (116) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "I-5", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| I-5 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 1,876 no ZIP in the county's record (147), 20121 (142), 20151 (423), 20153 (1), 20171 (58), 20190 (67), 20191 (3), 22015 (28), 22030 (54), 22031 (134), 22032 (4), 22039 (4), 22042 (29), 22043 (23), 22046 (4), 22079 (214), 22082 (1), 22102 (35), 22150 (61), 22151 (63), 22153 (177), 22161 (1), 22180 (2), 22182 (47), 22303 (2), 22310 (36), 22312 (116) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "I-5", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| I-6 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 187 no ZIP in the county's record (31), 20120 (3), 20151 (1), 22015 (1), 22046 (2), 22079 (104), 22150 (2), 22151 (23), 22159 (1), 22304 (7), 22312 (12) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "I-6", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| I-6 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 187 no ZIP in the county's record (31), 20120 (3), 20151 (1), 22015 (1), 22046 (2), 22079 (104), 22150 (2), 22151 (23), 22159 (1), 22304 (7), 22312 (12) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "I-6", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| PCC / Secondary Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | no parcels loaded | A | Sec. 4101 Read from the use table: Table 4101.2, row "Portable Storage Container", column "PCC / Secondary", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| PCC / Secondary (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | no parcels loaded | A/AP | Sec. 4101 Read from the use table: Table 4101.2, row "Portable Storage Container", column "PCC / Secondary", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| PDC / Secondary Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H and Sec. 2105.4.C(1); administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H and Sec. 2105.4.C(1); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b), Sec. 2105.4.C(1)(a), Sec. 2105.4.C(1)(b), Sec. 2105.4.C(1)(c), Sec. 2105.4.C(1)(d), Sec. 2105.4.C(1)(b)1, Sec. 2105.4.C(1)(b)2, Sec. 2105.4.C(1)(b)3: Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. … Secondary uses are only permitted in a PDC District containing one or more principal uses. … The gross floor area of all secondary uses may not exceed 75 percent of the total gross floor area in the development, unless modified by the Board to implement the Comprehensive Plan. … Secondary uses must be designed as an integrated component of the planned development and must be designed to maintain and protect the character of adjacent properties. … Except for accessory outdoor dining in accordance with subsection 4102.7.L, any outdoor component of a commercial use must be shown on the final development plan. … Balconies, porches, decks, breezeways, stoops, and stairs that may be covered but have at least one open side; and … Breezeways that may be covered but have two open ends. … For the purpose of this subsection (b), an open side or open end has no more than 50 percent of the total area between the side(s), roof, and floor enclosed with railings, walls, or architectural features. | no parcels loaded | A | Sec. 4101 Read from the use table: Table 4101.2, row "Portable Storage Container", column "PDC / Secondary", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| PDC / Secondary (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | no parcels loaded | A/AP | Sec. 4101 Read from the use table: Table 4101.2, row "Portable Storage Container", column "PDC / Secondary", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| PDH / Secondary Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | no parcels loaded | A | Sec. 4101 Read from the use table: Table 4101.2, row "Portable Storage Container", column "PDH / Secondary", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| PDH / Secondary (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | no parcels loaded | A/AP | Sec. 4101 Read from the use table: Table 4101.2, row "Portable Storage Container", column "PDH / Secondary", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| PRC / Convention/Conference Center Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | no parcels loaded | A | Sec. 4101 Read from the use table: Table 4101.2, row "Portable Storage Container", column "PRC / Convention/Conference Center", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| PRC / Convention/Conference Center (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | no parcels loaded | A/AP | Sec. 4101 Read from the use table: Table 4101.2, row "Portable Storage Container", column "PRC / Convention/Conference Center", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| PRC / Neighborhood Convenience Center Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | no parcels loaded | A | Sec. 4101 Read from the use table: Table 4101.2, row "Portable Storage Container", column "PRC / Neighborhood Convenience Center", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| PRC / Neighborhood Convenience Center (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | no parcels loaded | A/AP | Sec. 4101 Read from the use table: Table 4101.2, row "Portable Storage Container", column "PRC / Neighborhood Convenience Center", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| PRC / Residential Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | no parcels loaded | A | Sec. 4101 Read from the use table: Table 4101.2, row "Portable Storage Container", column "PRC / Residential", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| PRC / Residential (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | no parcels loaded | A/AP | Sec. 4101 Read from the use table: Table 4101.2, row "Portable Storage Container", column "PRC / Residential", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| PRC / Town Center Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | no parcels loaded | A | Sec. 4101 Read from the use table: Table 4101.2, row "Portable Storage Container", column "PRC / Town Center", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| PRC / Town Center (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | no parcels loaded | A/AP | Sec. 4101 Read from the use table: Table 4101.2, row "Portable Storage Container", column "PRC / Town Center", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| PRC / Village Center Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | no parcels loaded | A | Sec. 4101 Read from the use table: Table 4101.2, row "Portable Storage Container", column "PRC / Village Center", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| PRC / Village Center (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | no parcels loaded | A/AP | Sec. 4101 Read from the use table: Table 4101.2, row "Portable Storage Container", column "PRC / Village Center", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| PRM / Secondary Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H and Sec. 2105.5.C(2); administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H and Sec. 2105.5.C(2); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b), Sec. 2105.5.C(2)(a), Sec. 2105.5.C(2)(b), Sec. 2105.5.C(2)(b)1, Sec. 2105.5.C(2)(b)2, Sec. 2105.5.C(2)(b)3: Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. … Secondary uses may be permitted only in a PRM District where at least 50 percent of the total gross floor area in the development is devoted to multifamily dwellings. … The floor area for dwellings will be determined in accordance with the gross floor area definition, except that the following features will not be deemed gross floor area: … Balconies, porches, decks, breezeways, stoops, and stairs that may be roofed but that have at least one open side; or … Breezeways that may be covered but that have two open ends. … For the purposes of this subsection, an open side or open end has no more than 50 percent of the total area between the side(s), roof, and floor enclosed with railings, walls, or architectural features. | no parcels loaded | A | Sec. 4101 Read from the use table: Table 4101.2, row "Portable Storage Container", column "PRM / Secondary", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| PRM / Secondary (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | no parcels loaded | A/AP | Sec. 4101 Read from the use table: Table 4101.2, row "Portable Storage Container", column "PRM / Secondary", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| PTC Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 533 no ZIP in the county's record (67), 22102 (432), 22182 (34) | A | Sec. 4101 Read from the use table: Table 4101.2, row "Portable Storage Container", column "PTC", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| PTC (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 533 no ZIP in the county's record (67), 22102 (432), 22182 (34) | A/AP | Sec. 4101 Read from the use table: Table 4101.2, row "Portable Storage Container", column "PTC", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-1 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 26,110 no ZIP in the county's record (1,933), 20120 (98), 20121 (30), 20124 (80), 20151 (54), 20170 (711), 20171 (1,356), 20190 (27), 20191 (74), 20194 (237), 22003 (800), 22015 (434), 22027 (57), 22030 (566), 22031 (1,068), 22032 (475), 22033 (532), 22039 (1,063), 22042 (316), 22043 (110), 22044 (35), 22066 (2,705), 22079 (1,110), 22101 (1,579), 22102 (1,905), 22124 (3,260), 22150 (429), 22151 (1), 22152 (104), 22153 (197), 22180 (203), 22181 (892), 22182 (2,744), 22303 (1), 22306 (5), 22309 (6), 22310 (236), 22312 (55), 22315 (622) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-1", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-1 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 26,110 no ZIP in the county's record (1,933), 20120 (98), 20121 (30), 20124 (80), 20151 (54), 20170 (711), 20171 (1,356), 20190 (27), 20191 (74), 20194 (237), 22003 (800), 22015 (434), 22027 (57), 22030 (566), 22031 (1,068), 22032 (475), 22033 (532), 22039 (1,063), 22042 (316), 22043 (110), 22044 (35), 22066 (2,705), 22079 (1,110), 22101 (1,579), 22102 (1,905), 22124 (3,260), 22150 (429), 22151 (1), 22152 (104), 22153 (197), 22180 (203), 22181 (892), 22182 (2,744), 22303 (1), 22306 (5), 22309 (6), 22310 (236), 22312 (55), 22315 (622) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-1", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-12 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 7,817 no ZIP in the county's record (218), 20120 (143), 20151 (25), 20170 (38), 20171 (104), 22003 (1,310), 22015 (180), 22030 (86), 22031 (873), 22032 (257), 22041 (379), 22042 (125), 22043 (284), 22044 (26), 22079 (485), 22101 (22), 22124 (81), 22151 (32), 22152 (128), 22180 (166), 22181 (420), 22182 (618), 22304 (148), 22306 (445), 22307 (74), 22309 (135), 22310 (313), 22312 (702) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-12", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-12 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 7,817 no ZIP in the county's record (218), 20120 (143), 20151 (25), 20170 (38), 20171 (104), 22003 (1,310), 22015 (180), 22030 (86), 22031 (873), 22032 (257), 22041 (379), 22042 (125), 22043 (284), 22044 (26), 22079 (485), 22101 (22), 22124 (81), 22151 (32), 22152 (128), 22180 (166), 22181 (420), 22182 (618), 22304 (148), 22306 (445), 22307 (74), 22309 (135), 22310 (313), 22312 (702) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-12", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-16 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 528 no ZIP in the county's record (8), 20121 (1), 22030 (2), 22041 (121), 22042 (48), 22043 (203), 22124 (18), 22309 (49), 22310 (78) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-16", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-16 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 528 no ZIP in the county's record (8), 20121 (1), 22030 (2), 22041 (121), 22042 (48), 22043 (203), 22124 (18), 22309 (49), 22310 (78) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-16", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-2 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 36,703 no ZIP in the county's record (1,416), 20120 (683), 20121 (75), 20124 (9), 20151 (537), 20170 (54), 20171 (1,832), 20191 (463), 20194 (16), 22003 (4,216), 22015 (172), 22027 (9), 22030 (1,195), 22031 (1,247), 22032 (4,060), 22033 (423), 22039 (61), 22041 (1,090), 22042 (475), 22043 (436), 22044 (753), 22066 (94), 22079 (25), 22101 (3,097), 22102 (778), 22124 (365), 22150 (376), 22151 (198), 22152 (1,145), 22153 (867), 22180 (118), 22181 (1,218), 22182 (1,733), 22207 (59), 22213 (2), 22306 (1,352), 22307 (459), 22308 (682), 22309 (3,310), 22310 (326), 22312 (1,274), 22315 (3) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-2", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-2 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 36,703 no ZIP in the county's record (1,416), 20120 (683), 20121 (75), 20124 (9), 20151 (537), 20170 (54), 20171 (1,832), 20191 (463), 20194 (16), 22003 (4,216), 22015 (172), 22027 (9), 22030 (1,195), 22031 (1,247), 22032 (4,060), 22033 (423), 22039 (61), 22041 (1,090), 22042 (475), 22043 (436), 22044 (753), 22066 (94), 22079 (25), 22101 (3,097), 22102 (778), 22124 (365), 22150 (376), 22151 (198), 22152 (1,145), 22153 (867), 22180 (118), 22181 (1,218), 22182 (1,733), 22207 (59), 22213 (2), 22306 (1,352), 22307 (459), 22308 (682), 22309 (3,310), 22310 (326), 22312 (1,274), 22315 (3) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-2", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-20 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 17,328 no ZIP in the county's record (109), 20121 (812), 20151 (581), 20191 (169), 22003 (3,094), 22015 (303), 22030 (10), 22031 (577), 22032 (193), 22033 (262), 22041 (390), 22042 (706), 22043 (752), 22044 (63), 22046 (488), 22060 (1), 22079 (762), 22101 (35), 22102 (1,295), 22124 (778), 22150 (106), 22151 (1), 22152 (51), 22153 (1), 22180 (4), 22181 (277), 22182 (156), 22302 (31), 22303 (63), 22306 (915), 22307 (1,465), 22309 (2,420), 22310 (114), 22311 (106), 22312 (238) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-20", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-20 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 17,328 no ZIP in the county's record (109), 20121 (812), 20151 (581), 20191 (169), 22003 (3,094), 22015 (303), 22030 (10), 22031 (577), 22032 (193), 22033 (262), 22041 (390), 22042 (706), 22043 (752), 22044 (63), 22046 (488), 22060 (1), 22079 (762), 22101 (35), 22102 (1,295), 22124 (778), 22150 (106), 22151 (1), 22152 (51), 22153 (1), 22180 (4), 22181 (277), 22182 (156), 22302 (31), 22303 (63), 22306 (915), 22307 (1,465), 22309 (2,420), 22310 (114), 22311 (106), 22312 (238) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-20", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-3 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 68,283 no ZIP in the county's record (2,029), 20120 (2,083), 20121 (345), 20124 (1,773), 20151 (936), 20170 (3,100), 20171 (2,798), 20191 (408), 22003 (5,025), 22015 (4,194), 22027 (256), 22030 (520), 22031 (458), 22032 (2,172), 22033 (2,651), 22039 (45), 22041 (776), 22042 (1,009), 22043 (1,246), 22044 (913), 22046 (215), 22060 (20), 22079 (408), 22101 (4,663), 22102 (65), 22124 (53), 22150 (2,056), 22151 (4,441), 22152 (2,256), 22153 (3,759), 22180 (1,084), 22181 (346), 22182 (1,093), 22204 (17), 22206 (3), 22302 (22), 22303 (302), 22306 (1,421), 22307 (809), 22308 (4,263), 22309 (1,895), 22310 (3,852), 22311 (508), 22312 (1,102), 22315 (893) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-3", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-3 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 68,283 no ZIP in the county's record (2,029), 20120 (2,083), 20121 (345), 20124 (1,773), 20151 (936), 20170 (3,100), 20171 (2,798), 20191 (408), 22003 (5,025), 22015 (4,194), 22027 (256), 22030 (520), 22031 (458), 22032 (2,172), 22033 (2,651), 22039 (45), 22041 (776), 22042 (1,009), 22043 (1,246), 22044 (913), 22046 (215), 22060 (20), 22079 (408), 22101 (4,663), 22102 (65), 22124 (53), 22150 (2,056), 22151 (4,441), 22152 (2,256), 22153 (3,759), 22180 (1,084), 22181 (346), 22182 (1,093), 22204 (17), 22206 (3), 22302 (22), 22303 (302), 22306 (1,421), 22307 (809), 22308 (4,263), 22309 (1,895), 22310 (3,852), 22311 (508), 22312 (1,102), 22315 (893) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-3", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-30 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 6,428 no ZIP in the county's record (6), 20190 (44), 22041 (754), 22043 (252), 22044 (1,617), 22102 (2,497), 22180 (1), 22303 (1,224), 22306 (30), 22310 (2), 22312 (1) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-30", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-30 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 6,428 no ZIP in the county's record (6), 20190 (44), 22041 (754), 22043 (252), 22044 (1,617), 22102 (2,497), 22180 (1), 22303 (1,224), 22306 (30), 22310 (2), 22312 (1) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-30", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-4 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 16,986 no ZIP in the county's record (365), 22003 (787), 22027 (78), 22030 (4), 22031 (29), 22042 (4,980), 22043 (2,349), 22046 (1,265), 22079 (19), 22101 (301), 22124 (32), 22150 (1,788), 22151 (143), 22152 (38), 22180 (9), 22181 (63), 22182 (442), 22203 (2), 22206 (1), 22213 (7), 22302 (1), 22303 (789), 22306 (518), 22307 (1,208), 22310 (1,219), 22312 (454), 22315 (95) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-4", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-4 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 16,986 no ZIP in the county's record (365), 22003 (787), 22027 (78), 22030 (4), 22031 (29), 22042 (4,980), 22043 (2,349), 22046 (1,265), 22079 (19), 22101 (301), 22124 (32), 22150 (1,788), 22151 (143), 22152 (38), 22180 (9), 22181 (63), 22182 (442), 22203 (2), 22206 (1), 22213 (7), 22302 (1), 22303 (789), 22306 (518), 22307 (1,208), 22310 (1,219), 22312 (454), 22315 (95) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-4", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-5 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 11,400 no ZIP in the county's record (483), 20120 (118), 20121 (1,318), 20151 (497), 20170 (5), 22003 (541), 22015 (1,061), 22027 (107), 22031 (324), 22032 (473), 22033 (456), 22042 (69), 22043 (37), 22060 (1), 22079 (557), 22101 (111), 22124 (137), 22150 (246), 22151 (1), 22152 (617), 22153 (1,139), 22180 (59), 22181 (78), 22182 (121), 22303 (97), 22306 (811), 22307 (1), 22310 (237), 22312 (90), 22315 (1,608) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-5", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-5 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 11,400 no ZIP in the county's record (483), 20120 (118), 20121 (1,318), 20151 (497), 20170 (5), 22003 (541), 22015 (1,061), 22027 (107), 22031 (324), 22032 (473), 22033 (456), 22042 (69), 22043 (37), 22060 (1), 22079 (557), 22101 (111), 22124 (137), 22150 (246), 22151 (1), 22152 (617), 22153 (1,139), 22180 (59), 22181 (78), 22182 (121), 22303 (97), 22306 (811), 22307 (1), 22310 (237), 22312 (90), 22315 (1,608) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-5", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-8 Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 21,478 no ZIP in the county's record (600), 20120 (1,731), 20121 (2,235), 20151 (539), 20170 (798), 20191 (165), 22003 (332), 22015 (791), 22030 (220), 22031 (1,009), 22032 (1,164), 22033 (344), 22041 (79), 22042 (51), 22043 (719), 22044 (58), 22079 (1,321), 22101 (586), 22102 (178), 22124 (124), 22150 (471), 22151 (295), 22152 (943), 22153 (640), 22180 (83), 22181 (726), 22182 (299), 22303 (1,167), 22306 (402), 22307 (638), 22309 (695), 22310 (1,440), 22312 (169), 22315 (466) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-8", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-8 (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 21,478 no ZIP in the county's record (600), 20120 (1,731), 20121 (2,235), 20151 (539), 20170 (798), 20191 (165), 22003 (332), 22015 (791), 22030 (220), 22031 (1,009), 22032 (1,164), 22033 (344), 22041 (79), 22042 (51), 22043 (719), 22044 (58), 22079 (1,321), 22101 (586), 22102 (178), 22124 (124), 22150 (471), 22151 (295), 22152 (943), 22153 (640), 22180 (83), 22181 (726), 22182 (299), 22303 (1,167), 22306 (402), 22307 (638), 22309 (695), 22310 (1,440), 22312 (169), 22315 (466) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-8", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-A Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 13 22066 (7), 22079 (1), 22124 (3), 22182 (2) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-A", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-A (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 13 22066 (7), 22079 (1), 22124 (3), 22182 (2) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-A", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-C Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 9,951 no ZIP in the county's record (645), 20120 (1,984), 20121 (425), 20124 (1,843), 20151 (577), 20152 (1), 22030 (1,696), 22039 (2,775), 22060 (2), 22079 (3) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-C", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-C (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 9,951 no ZIP in the county's record (645), 20120 (1,984), 20121 (425), 20124 (1,843), 20151 (577), 20152 (1), 22030 (1,696), 22039 (2,775), 22060 (2), 22079 (3) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-C", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-E Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 7,380 no ZIP in the county's record (1,087), 20171 (8), 20190 (47), 20191 (68), 20194 (1), 20195 (1), 22039 (5), 22066 (3,320), 22079 (1,082), 22101 (4), 22102 (639), 22124 (340), 22181 (424), 22182 (353), 22308 (1) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-E", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-E (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 7,380 no ZIP in the county's record (1,087), 20171 (8), 20190 (47), 20191 (68), 20194 (1), 20195 (1), 22039 (5), 22066 (3,320), 22079 (1,082), 22101 (4), 22102 (639), 22124 (340), 22181 (424), 22182 (353), 22308 (1) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-E", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-MHP Varies Depends: by right as an accessory use, only if the use is a type or location that Sec. 4102.8.H(1) allows here and the use stays within the limits in Sec. 4102.8.H; administrative permit, only if the use is a type or location that Sec. 4102.8.H(7)(a) allows here and the use stays within the limits in Sec. 4102.8.H(7)(b); this table cell allows the use in more than one way (by right as an accessory use or administrative permit), and the use standards in Sec. 4102.8.H set which way applies when the use standards in Sec. 4102.8.H allow it this way Sec. 4102.8.H(1), Sec. 4102.8.H(7)(a), Sec. 4102.8.H(2), Sec. 4102.8.H(4), Sec. 4102.8.H(7)(b): Portable storage containers are allowed as a temporary use only on lots containing a dwelling and may be located in any yard. … Only in instances where a dwelling has been destroyed or damaged by casualty and only when such dwelling is to be rebuilt or repaired. … Portable storage containers are permitted for the following time periods: (a) On a lot containing 36,000 square feet or less and developed with a single-family detached dwelling, for a period not to exceed 30 consecutive days within a six-month period. (b) On a lot containing more than 36,000 square feet and developed with a single-family detached dwelling, for a period not to exceed 60 consecutive days within a six-month period. (c) On lots developed with single-family attached, stacked townhouse, or multifamily dwellings, for a period not to exceed seven consecutive days within a six-month period. (d) Where a dwelling has been damaged by casualty, a period of time established in accordance with subsection 4102.8.H(7) below. … Portable storage containers must not exceed a cumulative gross floor area of 130 square feet for each dwelling unit. … An administrative permit may be issued for a period not to exceed six months or for the period of an active building permit, whichever is shorter. This permit may be extended by the Zoning Administrator if construction of the dwelling is being diligently pursued. | 2 22030 (1), 22306 (1) | A | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-MHP", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
| R-MHP (same district) when the use is a type or location that Sec. 4102.8.H(1) allows here | 2 22030 (1), 22306 (1) | A/AP | Sec. 4101 Read from the use table: Table 4101.1, row "Portable Storage Container", column "R-MHP", reads "A/AP". Sec. 4101.1 says: I. If a cell in Table 4101.1 or Table 4101.2 contains more than one approval type, there is more than one possible way to establish the use, as referenced in the related use standards for the specific use. For example, when a cell contains a “P” as well as an “SE” or “SP,” if the use does not meet the standards when permitted by right, it may be established with BZA or Board approval in accordance with the applicable special exception or special permit standards and procedures. |
Pro and reports for Fairfax County, VA are coming soon.
We use this email only to tell you when Fairfax County, VA launches. We never share it.
This answer is good through July 1, 2026 — that is the date the ordinance we hold runs to, as published by Fairfax County. We last checked with the county on September 14, 2026 and found nothing newer. That is a check on that date, not a promise about today.
(none) above means a parcel we could not place inside any zoning district on the county's zoning map — 1,697 of them. We hold no zone on the parcel record we fetch from the county, so this is our reading of its map rather than a blank in its data.Sale history and assessed values from Fairfax County Department of Tax Administration records, retrieved October 5, 2026.
Built from scripts/build_reverse_index.py, generated 2026-10-11T20:59:04+00:00.