Washington, DC · Title 11 DCMR (2016 Zoning Regulations)
Permits medium to high density mixed-use development with a balance of uses
Development standards in ARTS-4
Maximum FAR
6
Maximum height
90 ft
Maximum lot coverage
75%
Rear setback
12 ft
By-right FAR varies by building type: Non-Residential 3; Residential (IZ) 7.2; Residential 6
Development standards for this market are not yet checked against a committed copy of the ordinance. Use the ordinance link below as the authoritative source.
Permitted uses in ARTS-4
AllowedHealth care facility (small, up to 6 persons) Health care facility for not more than 6 persons (not including resident supervisors or staff and their families), or not more than 8 persons including resident supervisors or staff, provided persons being cared for shall not exceed 6; matter-of-right in MU-Use Group G; Subtitle U §517.1(b)
ConditionalAutomobile or motorcycle sales or repair Special exception required; use must not be objectionable due to noise or fumes; must not cause dangerous traffic conditions; all facilities including storage must be within a building; no portion within 50 ft of R, RF, RA, MU-1, MU-2, MU-15, MU-16, or MU-23 zone; Subtitle U §518.1(a)
ConditionalCollege or university (full campus) Special exception required for college or university campus including hospital, dormitory, fraternity or sorority house; subject to Subtitle X conditions; Subtitle U §518.1(e)
ConditionalLight manufacturing, processing, fabricating, or milling Special exception required; must comply with PDR zone external effects standards; no adverse effects on adjoining properties; no dangerous traffic conditions; no outdoor storage; Subtitle U §518.1(j)
ConditionalWarehouse or wholesale use Special exception required; Subtitle U §518.1(n)
Not AllowedChemical manufacturing, storage, or distribution Specifically prohibited in MU-Use Group G; Subtitle U §519.1(f)
Not AllowedDrive-through operation Drive-through operation as either principal or accessory use is specifically prohibited in MU-Use Group G; Subtitle U §519.1(g)
Not AllowedFirearms retail sales establishment Firearms retail sales establishments as principal or accessory use specifically prohibited in MU-Use Group G; Subtitle U §519.1(i)
Not AllowedGasoline service station Specifically prohibited in MU-Use Group G; Subtitle U §519.1(j)
Not AllowedOutdoor material storage Specifically prohibited in MU-Use Group G; Subtitle U §519.1(m)
Not AllowedParking lot (surface) Surface parking lot prohibited in MU-Use Group G except Ballpark temporary surface lots per Subtitle U §517.1(c); Subtitle U §519.1(o)
Not AllowedAnimal boarding (non-veterinary) Animal care and boarding prohibited except for a veterinary office or hospital; Subtitle U §519.1(r)
"Conditional" means the use generally requires a public hearing or special-exception approval — a very different timeline and risk profile from a by-right permit.
This is the zone. What about the parcel?
Zone rules are the starting point — the answer for a specific property also depends on lot
size, overlays, existing improvements and site conditions. Run a free address lookup to see
what applies to one property.
Development standards are derived from the DC Office of Zoning's published development-standards table and checked against Title 11 DCMR; use permissions follow Subtitle U.